1, the electrical performance:
* Temperature range: -50 *C - 110 *C
* Temperature range: -50 *C - 110 *C
* Temperature measurement error: +- 0.5 *C
* Sensor Type: NTC (10K/3435)
* control accuracy: 1 *C
* Operating voltage: DC 12V
* Current: MAX200MA
* relay contact current: AC 5A/220V
* Data retention: a
* Operating temperature: 0 *C - 50 *C
* Storage temperature: -10 *C - 60 *C
with sensor free:


2.Wiring diagram
Terminal 1 and 2: Normally open contact relay
Terminals 3 and 4: 12V power connection
Terminal 5 and 6: Short circuit after locking thermostat factory parameter settings, the user can not modify.
Terminal 7 and 8: temperature sensor connection
Note: The "load" refers to the controlled heating or cooling equipment
3 Button Description:
1). RST: Press the RST key to switch on and off, press the RST key in the off state once the boot, the boot
State according to RST button for three seconds and hold off.
2). SET:
A: Press the SET key once to enter the temperature control settings, press “UP”or “DOWN” to adjust, press “UP”or "DOWN” button for three seconds does not
Quickly put into adjustment mode. Press the SET button again to exit setting mode.
| Menu code selection | ||||
| Symbol | Details | Setting range | Factory settings | Unit |
| HC | Heating / cooling | H/C | C | |
| D | Hysteresis | 1 -- 15 | 5 | *C |
| LS | Lowest setting limits | -50 -- 110 | -50 | *C |
| HS | The maximum limit set | -50 -- 110 | 110 | *C |
| CA | Temperature correction | -5 -- 5 | 0 | *C |
| PT | Delay time | 0 -- 10 | 1 | Min |
5, Caution:
* Cooling, heat load must not exceed the output contact, or may cause machine damage and cause a fire.
Disaster.
* A variety of connection wires and terminals connected to pressure well, otherwise, will cause the machine reliability.
* Please separate power wiring, relays, sensors, otherwise it will damage the machine.