G-wholesale! 100w co2 laser power supply for laser tube laser cutting machine quality assurance!
- Processing Time:
- Shiping out within 3 days
Smarter Shopping, Better Living!
co2 laser power supply
100w-150w
Input Voltage | Input Voltage | AC220V or AC110V | |
| AC Frequency | 47-440Hz | |
| Cold surge current | ≤60A(AC220V input) | ≤60A(AC220V input) |
| Leak current | ≤0.7mA(AC220V input) | ≤0.7mA(AC220V input) |
Output | Max output Voltage | DC50KV | |
| Max Output current | DC 38mA | |
Efficiency | when≤92%load down | ||
Time no-failure | ≤10000 hours | ||
Response speed | ≤1ms(the time from output of switch signal to 90%of initial setting current) | ||
Control port | TLL electricity level switch control, valid electricity has high/low level choices | ||
Vollage-resisting | Input-Output ,input-machine hull: 1500V 10mA 60s AC output cathode and machine hull connection | ||
Protection | Can be used an opening way in a short time(request the outer shell be good to connent the ground avoid arcing between anode and machine hull connection in the machine) | ||
Vsage environment | Work temperature:(-10-40)Relative humidity:≤90% | ||
Cooling Type | The compuisive air cooling | ||
size | L×W×H=350×240×95(mm) | ||
80w
Input Voltage | Input Voltage | AC220V or AC110V | |
| AC Frequency | 47-440Hz | |
| Cold surge current | ≤60A(AC220V input) | ≤60A(AC220V input) |
| Leak current | ≤0.7mA(AC220V input) | ≤0.7mA(AC220V input) |
Output | Max output Voltage | DC 40KV | |
| Max Output current | DC 28mA | |
Efficiency | when≤92%load down | ||
Time no-failure | ≤10000 hours | ||
Response speed | ≤1ms(the time from output of switch signal to 90%of initial setting current) | ||
Control port | TLL electricity level switch control, valid electricity has high/low level choices | ||
Vollage-resisting | Input-Output ,input-machine hull: 1500V 10mA 60s AC output cathode and machine hull connection | ||
Protection | Can be used an opening way in a short time(request the outer shell be good to connect the ground avoid arcing between anode and machine hull connection in the machine) | ||
Vsage environment | Work temperature:(-10-40) Relative humidity:≤90% | ||
Cooling Type | The compuisive air cooling | ||
size | L×W×H=210×160×95(mm) | ||
60w
Input Voltage | Input Voltage | AC220V or AC110V | |
| AC Frequency | 47-440Hz | |
| Cold surge current | ≤60A(AC220V input) | ≤30A(AC110V input) |
| Leak current | ≤0.7mA(AC220V input) | 0.4mA(AC220V input) |
Output | Max output Voltage | DC 35KV | |
| Max Output current | DC 23mA | |
Efficiency | when≤90%load down | ||
Time no-failure | ≤10000 hours | ||
Response speed | ≤1ms(the time from output of switch signal to 90%of initial setting current) | ||
Control port | TLL electricity level switch control, valid electricity has high/low level choices | ||
Vollage-resisting | Input-Output ,input-machine hull: 1500V 10mA 60s AC output cathode and machine hull connection | ||
Protection | Can be used an opening way in a short time(request the outer shell be good to connect the ground avoid arcing between anode and machine hull connection in the machine) | ||
Usage environment | Work temperature:(-10-40) Relative humidity:≤90% | ||
Cooling Type | The compuisive air cooling | ||
size | L×W×H=210×160×95(mm) | ||
40w
Input Voltage | Input Voltage | AC220V or AC110V | |
| AC Frequency | 47-440Hz | |
| Cold surge current | ≤60A(AC220V input) | ≤30A(AC110V input) |
| Leak current | ≤0.7mA(AC220 input) | ≤0.4mA(AC220V input |
Output | Max output Voltage | DC 25KV | |
| Max Output current | DC 20mA | |
Efficiency | when≤92%load down | ||
Time no-failure | ≤10000hours | ||
Response speed | ≤1ms(the time from output of switch signal to 90%of initial setting current) | ||
Control port | TLL electricity level switch control, valid electricity has high/low level choices | ||
Vollage-resisting | Input-Output ,input-machine hull: 1500V 10mA 60s AC output cathode and machine hull connection | ||
Protection | Can be used an opening way in a short time(request the outer shell be good to connect the ground avoid arcing between anode and machine hull connection in the machine) | ||
Usage environment | Work temperature:(-10-40) Relative humidity:≤90% | ||
Cooling Type | The compuisive air cooling | ||
size | L×W×H=210×160×95(mm) | ||