YKDPZ-B 18chs DC Power Distribution Cabinet
- Processing Time:
- Shiping out within 7 days
Smarter Shopping, Better Living!
YKDPZ-B 18chs DC Power Distribution Unit-PDU-
DC Power Distribution Cabinet
DC Distribution System
DC Distribution Box
PDU
DC Distribution Unit
DC Power Distribution Panel
DC Power Distribution Cabinet
PDU
rack PDU
PDU for cabinet
Switched PDU
PDU socket
intelligent PDU
Rack PDU power
PDU socket for cabinet
Cabinet PDU socket
Cabinet PDU
PDU of cabinet
DC Input PDU
AC Input PDU
Introduction.
YKDPZ-B is a DC power distribution system module with 19inch standard structure, small size , easy to install and use. There is A-B 2chs input, multi-channels output (max 18chs). Visual-aural alarm when there is failure. LED display running status
This equipment has excellent performance and reliable quality. It’s widely used in Telecom, BTS, Mobile, Unicom, electric power, army, public security, etc.
Technical specification
Item | Technical specification |
Rated voltage | -48V |
Insulation resistance | ≥30MΩ |
Insulating intensity | Input—housing AC1000V,50Hz,1minute Output-housing . AC1000V,50Hz,1minute |
Input channels | 2 channels DC-48V,100A |
Output channels | 18 channels 14 channels DC-48V,63A 2 channels DC-48V,32A 2 channels DC-48V,20A |
Alarm | Visual-aural alarm signal. When there is any channel is failed, Red LED ON and buzzer sounds. |
Working environment | Working temperature 0°C~40°C Related humility ≤90% (+20±5°C) atmospheric pressure70Kpa~106Kpa |
Dimension | L*D*H(mm)485 mm *175 mm *85 mm |
Weight | 5.5Kg |
Packing. | 520 *130 mm *200mm, 6.0kg |
Visual-Aural Alarm
This DC power distribution system module can display the running status of all the channels. When there is failure or break, Red LED ON and buzzer sounds and giving the alarming signal to third party system for alarming
If you want to stop alarm, please press “SA” button. If there are others failure right now, there will be no alarm.
When there is failure again, RED LED still ON, and it will not OFF until the failure is eliminated and switch is turn on
Installation and connection
4.1 install
Easy and simple install. Standard 3.0U structure, can install in the standard 19 inch cabinet.
4.2 Connection
All the connection is on the rear panel.
Please connect with the anode, cathode and grounding as required. Please tighten the connection screw and nut. Connection must be steady and reliable to reduce the resistance.
4.3 Note.
Please don’t change or replace any wiring or air switch etc inside the dc power distribution system module. If you want to change or replay, please contact with manufactures.
Notes
Must be engineer or technician or electrician to install the DC power distribution system !
5.1 Open the package, check the DC power distribution system module appearance and accessories is damaged or not in transportation.
5.2 Check before electrify. check the appearance, power wiring, terminal board also the screw is loosen / damaged or not.
5.3 Check the INPUT DC power source is as require
5.4 Make sure the correct connection of anode “+” and cathode “-”
Customer Satisfaction
Please don't hesitate to contact us if you have any questions or concerns before or after your purchase. We are committed to your 100% satisfaction.
Payment
Notes
1. The buyer are responsible for any insurance you think necessary.
2. The processing time for a specific order varies with the product type and stock status. Mostly, processing time can be 3 to 15 working days.
3. All items must be returned in their original condition, in order to qualify for a refund or exchange of goods.
4.Items returned after 7 days of delivery are only eligible for repair.
5. The buyer is responsible for all shipping costs incurred.
Feedback
1. Since your feedback is very important to our business's development, we sincerely invite you to leave positive feedback for us if you are satisfied with our product and service. It'll just take you 1 minute.
2. Please contact us before leaving any negative or neutral feedback. We will work with you to solve any problems. Thank you!