Product Description

now the light color is red , if changer to green , pls tell me before i send it to you
if you buy many , can change their color.
Fingerprint lock, password lock,safe lock, digital locks, safes locks, electronic lock for safe,
Technique: supplies:
DC 3.6~6.0V
work Current: 100mA (typical value)
peak value Current: 150mA
refers to enters likely:
Fingerprint image input time: "0.5 seconds
window size: 14 × 18mm
match the way:
comparison mode (1:1)
search method (1: n)
Feature File: 256-byte
template file: 512 MB
storage capacity: 120
Safety Level: 5 (from low to high: 1,2,3,4,5)
False Accept Rate (FAR): <0.001% (Safety grade 3)
False Reject Rate (FAR): <0.1% (the security level of 3)
Search time: "1.0 seconds (1:1000, the mean)
host computer interface: UART (TTL logic level) or USB1. 1
Communications baud rate (UART): (9600 × N) bps where N = 1 ~ 12 (default value of N = 6, namely, 57600bps)
working environment:
Temperature: -20 ° C to +40 ° C
Relative Humidity: 40% RH -85% RH (non-condensing)
Storage Environment: Temperature: -40 ° C to +85 ° C
Relative humidity: <85% H (non-condensing)
Dimensions: (LXWXH)
split: Module: 28 × 19 × 8.5mm
Fingerprint Sensor: 56 × 20 × 21.5mm
Product Name: Intelligent fingerprint lock SC760
The version: V1.1 Patent Number: 200830098931.5
First, the system power-on: Power-on self-test ring“di di” ,system enter standby mode.
Second, add fingerprint:
add the first fingerprint: stand-by mode, Press the Add button, then it will light up the red light, press on the finger tips buzzer, ring "Di" , raised your finger, waiting for it light up red once again, Press on the same finger, if right acquisition is to Ring a long "Di." its System then continue to wait for the operation or after 10 seconds entering the standby mode automatically.
add other fingerprint: stand-by mode, Press the Add button, the first administrator to conduct fingerprint verification, if validation Successfully , Press the "Add" Or "Del." Button, choose to add the fingerprints of storage space, if you choose "02 ~ 03" is the administrator rights, and the rest are General user rights (have no authorized to add or remove any fingerprints), after choose a good space then press "Start" button to start a new fingerprint registration, operating methods is the same as the first fingerprint.
Third, delete fingerprint:
In standby mode, press "Del." Key, first administrator to conduct fingerprint verification, validation Successfully, Press the "Add" (the front) or "Del." (Next)to choose delete which fingerprint, then Press "Start" button to confirm the deletion. (First fingerprint In this menu can not be deleted)
Fourth, how to open or close?
open: In standby mode, press the "Start" button, it will light up the red light, press the Registered fingerprint to authentication, if right ,the indentation latch can be opened door; when the fingerprint system have no Registered fingerprint, " Start "button latch automatically after the indent, every user can open the door. (When the latch indent, users within 10 seconds not open door, the latch will pop up automatically re-lock the door)
close: when the door opened and the system of standby status, press the "Start" button, the latch will pop up automatically. Or directly related to the Closed door, the latch will pop up automatically.
Fifth, vibration alarm (optional)
open vibration alarm: in standby mode, press the "Func." Button, the screen flashes the beginning of speakers, press the "Add" button or "Del." Button to choose the vibration function of the police and customs opened, and showed that the three speakers on behalf of the ")))" vibration function to open, after a good choice ,"Start" button to confirm (vibration alarm functions will remain in effect open, only failure when you close it).
close vibration alarm: in standby mode, press the "Func." Key at this time need to enter fingerprint authentication before allowing access to closed Menu. After the adoption of the same can be verified by the "Add" button or "Del." Button to confirm selection.
Sixth, remind Low voltage lower
system uses four 1.5V alkaline batteries, battery full, showed signs of solid battery, if battery voltage lower than 4.5V, when open the door it remind the "drip, drip, Di" three times to tell the users to replace the battery .
if you don’t replace, you can use Emergency key to open. or External power supply
Seven, the system initialization
Press on the green button for 5 seconds, the system will resume initialization settings, remove all fingerprints.
Eight, the system parameters
Operating voltage: 4.0V ~ 6.8V under-voltage reminder: 4.5 ± 0.2
Current work: <200mA standby current: <10uA
Fingerprint capacity: Admin (administrator) Group 3 fingerprints, User (user) Group 96